• Article highlight
  • Article tables
  • Article images

Article History

Received : 03-05-2024

Accepted : 09-09-2024



Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 2

PDF Downloaded: 8


Get Permission Das, Roy, Hembrom, Bhattacharya, and Choudhury: Comparison of intermittent intravenous bolus of phenylephrine and noradrenaline in management of spinal anesthesia induced hypotension in elective cesarean section: A randomized controlled trial


Introduction

Recently, phenylephrine, a pure alpha1 agonist, has become the 1st line agent for treating spinal anaesthesia-induced hypotension in obstetrics.1, 2 The main drawback of using this agent is a dose-related decrease in heart rate (HR) and cardiac output (CO) which may adversely affect uteroplacental circulation.1, 3, 4 Though it may not cause any serious problems with a normal foetus in elective lower segment caesarean section (LSCS),  in case of emergency, where the foetus is already compromised, it can affect more.2 In this context, a drug like noradrenaline (NA) is advantageous as it has both direct positive chronotropic and baroreceptor reflex-mediated negative chronotropic effects with the overall effect on HR considered to be approximately neutral, and contributes to an overall increase in CO and BP.5, 6, 7

Many studies have evaluated the efficacy of continuous infusion of inj. NA for management of spinal anaesthesia-induced hypotension during LSCS.2, 4, 6 However, there are not many studies that have evaluated the intermittent intravenous bolus dose of inj. NA for management of spinal anaesthesia-induced hypotension. Most clinicians favour the use of intermittent boluses of vasopressors rather than infusions as infusion pumps are costly, not easily available (especially in resource-poor setups), and difficult to operate. For these reasons, though Noradrenaline infusion is showing promising results for prophylaxis and treatment of maternal hypotension, it is not gaining much popularity in day-to-day practice.

Because of the above observations, our study was planned to compare the intermittent intravenous bolus of phenylephrine and noradrenaline in the management of spinal anaesthesia-induced hypotension in elective LSCS. The foetal outcome was also compared.

Materials and Methods

After obtaining approval from the institutional ethical committee (CTRI/2022/08/044815), this prospective randomized double-blind study was conducted following the Helsinki Declaration-2013, in the obstetrics operation theatre of a tertiary care centre in eastern India from August 2022 to April 2023 in ASA II pregnant patients of age 18 years and above undergoing elective LSCS under spinal Anaesthesia. Patient’s refusal to subarachnoid block, infection at the site of injection, height < 140cm and >180cm, patient in active labour, patient with any spine deformity, bleeding disorder, GDM, PIH, eclampsia, allergy to phenylephrine and norepinephrine, cardiac or neurological diseases, known allergy to the anaesthetic drugs used, systemic sepsis, failed/patchy block converted into general Anaesthesia were excluded from the study.

In this study, intermittent I.V. bolus dose of Phenylephrine was compared with intermittent I.V. bolus dose of Noradrenaline in the management of spinal anaesthesia-induced hypotension in elective LSCS. Two groups were compared in terms of the perioperative haemodynamic effects, side effect profiles, and foetal outcomes. When the MAP value falls 20% from the baseline, we define it as hypotension.8, 9 Heart Rate below 60 beats/minute (bpm) was defined as bradycardia.8

Patients were explained in detail about the procedure. After obtaining written informed consent, eligible study candidates were randomly allocated into two groups (Group A: Phenylephrine and Group B: Noradrenaline group), 51 in each group by closed envelope method. Anaesthesia machine, airway equipment, and drugs for resuscitation were kept ready before starting the procedure. Injection Phenylephrine was prepared with a concentration of 50 µg/ml and was labeled as 'DRUG A'. Inj. Noradrenaline was prepared as 4µg/ml and was labeled as 'DRUG B'. Study solutions were prepared by a senior Anaesthesiologist, who was given a written protocol for drug preparation. The Anaesthesiologist who administered the drug and recorded the data, and the study participants were unaware of the composition of the study drug administered. After the patient arrived in the operation theatre, I.V. access was secured with an 18G cannula, and ringer lactate was administered (15 ml/kg) in both groups. Monitoring included: SpO2, ECG, non-invasive blood pressure (NIBP), and HR. Baseline HR, mean arterial pressure (MAP), SPO2, and ECG were recorded. BP was recorded 3 times in 2-minute intervals before administering spinal anaesthesia. The mean of these three readings was taken as baseline MAP and HR. After antiseptic dressing and draping spinal anaesthesia was administered with 25µg (0.5ml) Fentanyl + 1.8ml Bupivacaine heavy (0.5%) @ 0.2 ml/sec rate with the patient in a sitting position with 27G Whitacre needle at L3-L4 intervertebral space after confirming free flow of CSF. Immediately after giving spinal anaesthesia patient was kept in a supine position with a wedge in the back as 15 degrees left lateral tilt. Mean arterial pressure was monitored at 3-minute intervals for 15 minutes, then at 5-minute intervals. After achieving a sensory block height up to T6 dermatome, LSCS was allowed. Patients were supplemented with oxygen @ 4-6lt/min through a face mask. Immediately after hypotension, 1 ml of DRUG A was administered to group A patients and 1 ml of DRUG B to the patients of group B. Nausea and vomiting were treated with inj. Ondansetron 4 mg intravenously. After delivery of the baby, blood from umbilical artery (UA) and umbilical vein (UV) was sent for arterial blood gas (ABG) analysis (pH, PO2, PCO2, HCO3-). Data regarding hypotension, bradycardia, the total number of bolus doses of Drug A and Drug B required, intraoperative nausea and vomiting, neonatal Apgar score at 1 min and 5 min, and umbilical cord blood gas analysis at birth were collected.

The sample size has been calculated with the help of Epi Info (TM) 3.5.3. The formula used for sample size calculation was:- n = 4pq/(L2); where, n = required sample size, p= 0.137 (as per the study by Singh P et al.),10 q = 1 – p, L = Margin of error. Here p= 0.137, q=1-p = 1-0.137 =0.863, 4pq = 4 x 0.137x 0.863 = 0.4729, L2 = 0.00462; n = 4pq/(L2) = 0.4729/0.00462= 102.3= 102. So, the number of patients required for this study was 102 with 87% power. For statistical analysis, data were entered into a Microsoft Excel spreadsheet and then analyzed by SPSS (version 27, SPSS Inc., Chicago, IL, USA) and GraphPad Prism version 5. Data had been expressed as mean and standard deviation (SD) for numerical variables, and count and percentages for categorical variables. Independent samples or unpaired samples were compared by two-sample t-tests for a mean difference. The chi-square test or Fischer’s exact test was used to compare Unpaired proportions, as appropriate. P-value ≤ 0.05 was interpreted statistically significant.

Figure 1

Consort diagram showing participants’ recruitment and flow

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/8aed3603-ae2d-46e5-a981-2fe5fba2891f/image/87427e32-9948-42c2-b0bf-c1d3d547bd75-uimage.png

Results

Data from 102 participants were analyzed. The two study groups (Group A and Group B) were comparable in terms of age, weight, height, and duration of pregnancy (Table 1).

From Figure 2, we can see that HR at 9 min, 12 min, 15 min, and 20 min after spinal Anaesthesia was significantly lower in group A than in group B with the HR of 51.05 ± 3.53 in group A and 88.76 ± 8.76 in group B (P-value: 0.00001), 51.21 ± 3.76 in group A and 86.13 ± 7.13 in group B (P-value: 0.0001), 51.94 ± 3.54 in group A and 84.8 ± 5.85 in group B (P-value: 0.0001), 68.58 ± 8.81 in group A and 83.25 ± 7.55 in group B (P-value: 0.003) at 9 minutes, 12 minutes, 15 minutes, and 20 minutes respectively. Even in some patients of group A, HR was as low as less than 50 bpm.

Figure 2

Graph demonstrating difference in HR at different time intervals

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/8aed3603-ae2d-46e5-a981-2fe5fba2891f/image/15e864bc-469c-4271-9b67-8d27fb63ebb3-uimage.png

No statistically significant difference was found between the groups in terms of mean arterial pressure. (Figure 3)

Figure 3

Graph demonstrating difference w.r.t MAP at different time intervals

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/8aed3603-ae2d-46e5-a981-2fe5fba2891f/image/9b28f6a3-f018-4009-8758-5df481f90725-uimage.png

No statistically significant difference was found between the two groups in terms of APGAR score at 1 minute and 5 minutes (Table 2). No statistically significant difference was found between the two groups concerning UA pH, UA PO2, UA PCO2, UA HCO3-, UV pH, UV PO2, UV PCO2, and UV HCO3- (Table 2). The incidence of nausea and vomiting in group A is 59% and in group B is 40% and the difference was statistically significant (P-value = 0.006). From Table 3, we can see that Group B patients received a greater number of bolus doses than Group A and the difference is statistically significant.

Table 1

Distribution of maternal characteristic details

Parameters

Group

Mean (SD)

p-value

Age

A

24.88 (3.05)

0.85

B

24.86 (3)

Height(cm)

A

159.27 (4.87)

0.806

B

159.96 (4.78)

Weight (Kg)

A

59.98 (4.74)

0.999

B

60.86 (5.09)

Period of Gestation (week)

A

37.62 (0.68)

0.65

B

37.57 (0.65)

Table 2

Comparison between group A and group B concerning UA & UV blood gas analysis and mean APGAR score

Parameters

Group

Mean (SD)

p-value

UA pH

A

7.42 (0.24)

0.242

B

7.38 (0.22)

UA PO2

A

14.563 (1.24)

0.18

B

16.014 (0.92)

UA PCO2

A

45.987 (2.24)

0.47

B

43.129 (1.82)

UA HCO3-

A

23.987 (1.8238)

0.15

B

24.68 (0.82)

UV pH

A

7.389 (0.94)

0.44

B

7.4 (0.82)

UV PO2

A

20.98 (2.89)

0.49

B

21.35 (1.92)

UV PCO2

A

40.897 (1.94)

0.33

B

41.67 (1.92)

UV HCO3-

A

22.989 (1.82)

0.27

B

23.67 (0.82)

APGAR 1 min

A

8.49 (0.50)

0.84

B

8.51 (0.51)

APGAR 5 min

A

8.55 (0.50)

0.56

B

8.49 (0.51)

Table 3

Comparison between group A and group B concerning the number of bolus doses given

Parameter

Group

Mean (SD)

P-value

No. of bolus doses

Group A

4.16 (1.36)

<0.00001

Group B

8.27 (1.51)

Discussion

The present study shows that both inj. phenylephrine (50µg bolus) and inj. noradrenaline (4µg bolus) has similar efficacy for the management of hypotension during LSCS under spinal anaesthesia without causing any adverse neonatal outcome. However, patients who received phenylephrine bolus experienced more episodes of bradycardia (HR up to 37/min) than the patients who received noradrenaline. This finding corroborates our hypothesis that using alpha1 agonists with beta1 adrenergic action has similar efficacy in maintaining BP without causing a significant decrease in HR compared to pure alpha1 agonists.

We have observed that patients of both groups maintained their BP throughout the whole duration of surgery. Differences in MAP were not statistically significant between the two groups. However, we have documented episodes of bradycardia in patients of group A after giving phenylephrine bolus without any increase in BP above the baseline. While comparing HR, differences in HR between both groups were statistically significant at 9 minutes, 12 minutes, and 15 minutes after giving spinal anaesthesia. But BP never went above the baseline at those above-mentioned times. The incidence of bradycardia was 41 among 51 patients in group A (82%) and 2 in group B (4%). During LSCS under spinal anaesthesia, maternal bradycardia may occur due to the Bainbridge reflex, or from the blockade of cardiac accelerator sympathetic fibres (T1-T4).8 Either mechanism would be counteracted by beta receptor-mediated agonistic activity.2, 6, 7 Therefore, norepinephrine demonstrated a better HR maintenance profile and lower incidence of bradycardia than the patients who received phenylephrine.5, 7

In the present study CO, SV, or SVR was not measured. But Xu S et al. in their meta-analysis found that noradrenaline was associated with greater CO and lower SVR than phenylephrine.2 Theoretically, this haemodynamic profile of noradrenaline may be potentially more favourable for maintaining perfusion in the uteroplacental bed and another peripheral vascular region.2, 7 The finding of our study is that group B patients had greater HR than group A. Due to more CO and lower SVR in patients receiving noradrenaline, there was a reflex increase in HR due to inhibition of the Bainbridge reflex and stimulation of the baroreceptor reflex. Singh J et al. found in their study that noradrenaline has less adverse effect on HR and greater CO compared to phenylephrine in preventing spinal anaesthesia-induced hypotension during LSCS.11 M. Heesen et al. found that noradrenaline preserved better haemodynamic stability compared to phenylephrine.12 Singh D et al. stated that phenylephrine causes serious bradycardia at the time of administration.13 Aidan M Sharkey et al. found that the haemodynamic profile offered by noradrenaline during caesarean delivery is superior to that of phenylephrine due to fewer fluctuations in HR and possibly CO.14 Similar results were obtained in the present study.

In the present study, the incidence of nausea and vomiting is significantly lower in patients who received noradrenaline. Contributing factors may include opioids as an adjuvant for spinal anaesthesia, hypotension, or uterine exteriorization.8, 15, 16 We used 25 µg of Fentanyl for every patient and uterine exteriorization was done in every case of our study population. Similar to the present study, Rai AV et al. have also observed a higher incidence of nausea and vomiting in the phenylephrine group than in the norepinephrine group.4 Less incidence of nausea and vomiting in the noradrenaline group may be due to better gut and cerebral perfusion, followed by less serotonin release and less stimulation of the chemoreceptor trigger zone (CTZ).17 This is an advantage of noradrenaline when compared to phenylephrine, as we have observed in the present study.

In our study, no significant difference in neonatal outcome was found between the two groups in terms of APGAR score (at 1min and 5 min), and UA and UV blood gas analysis at birth. Ngan Kee WD et al. also found in one of their studies that norepinephrine was non-inferior to phenylephrine for neonatal outcomes assessed by umbilical arterial pH and this result provided high-quality evidence supporting the foetal safety of norepinephrine in obstetric anaesthesia.18

We have used 50 µg of phenylephrine in group A and 4 µg of noradrenaline in group B. Warwick D. Ngan Kee et al. chose to study norepinephrine at a concentration of 6 µg/ml, which was estimated to be of equivalent potency to phenylephrine 100 µg/ml. This assumed a potency ratio for norepinephrine/phenylephrine of 16.7:1.18 In another study of dose-response comparison of norepinephrine and phenylephrine, Ngan Kee et al. calculated a potency ratio of 13.1:1 (norepinephrine 7.6 µg equivalent to phenylephrine 100 µg). 19 Qian J et al. found that the estimated relative potency for norepinephrine: phenylephrine was about 6:1. 20 In the present study, the number of bolus doses used for phenylephrine was 4.16±1.36, and for noradrenaline, it was 8.27±1.51. and the difference is statistically significant. So, it can be concluded that the potency of phenylephrine is more than noradrenaline. The reasons for this difference in potency between the two study drugs may be due to the greater duration of action of phenylephrine (15-20 min) than that of noradrenaline (5-10 min) and the difference in the dose of the bolus injection used in the present study.

A concern of norepinephrine injection is vasoconstriction and skin necrosis, as peripheral veins have been used in our study for injection of the study drugs. Chen D et al. studied the skin colour in patients infused with normal saline or 5, 10, and 15µg/kg/h norepinephrine and they observed that the incidence of pale skin was similar among the groups (3.3% vs 3.4% vs 20% vs 10.7%, respectively P=.089).5 Hasanin AM et al. and Nagan Kee WD et al. demonstrated the safety of norepinephrine for local tissue perfusion because noradrenaline was diluted before administration and was administered for a short duration. 7, 18 An equally potent solution of norepinephrine infusion or bolus dose has a theoretically similar vasoconstrictive action as phenylephrine.2, 21 In the present study, no skin changes were found in either of the groups.

No study subject experienced reactive hypertension after administration of the vasopressor agents in the present study. However, in a study conducted by Yasmin S. Hassabelnaby et al., reactive hypertension occurred in 9% of the study population for both 6µg/ml and 10µg/ml bolus doses of noradrenaline.22 Rai AV et al. used phenylephrine 100 μg/mL or norepinephrine 7.5 μg/mL in their study and reported reactive hypertension in 28.9% of patients who received phenylephrine and 4.4% of patients of Norepinephrine group.4 These findings do not corroborate the findings of the present study. It may be because a lower dose of noradrenaline was used in the present study than in the reference studies.

While conducting the study and in clinical practice also, it was found that phenylephrine is not effective in some patients. In those instances, other vasopressors were chosen as rescue agents. Žunić M et al. also mentioned the same problem in their study. 23

Limitations of the study include its single-center design, which may limit generalizability to broader populations. The exclusion of preeclamptic mothers also restricts applicability to this specific patient group. Additionally, we did not measure umbilical artery (UA) and umbilical vein (UV) levels of phenylephrine and noradrenaline, which could provide further insights into fetal exposure and effects during cesarean sections.

Conclusion

Our study demonstrates that both Phenylephrine and Noradrenaline are effective in managing spinal anesthesia-induced hypotension during elective LSCS when administered intermittently via IV bolus. However, Noradrenaline offers distinct advantages in preserving hemodynamic stability while exhibiting a reduced incidence of adverse effects compared to Phenylephrine. These findings highlight Noradrenaline as a preferred option in clinical practice for managing hypotension during LSCS under spinal anesthesia.

Source of Funding

None.

Conflict of Interest

None.

References

1 

I Šklebar T Bujas D Habek Spinal anaesthesia-induced hypotension in obstetrics: prevention and therapyActa Clin Croat201958Suppl 1905

2 

S Xu X Shen S Liu J Yang X Wang Efficacy and safety of norepinephrine versus phenylephrine for the management of maternal hypotension during cesarean delivery with spinal anesthesia: A systematic review and meta-analysisMedicine (Baltimore)2019985e14331

3 

K Theodoraki S Hadzilia D Valsamidis E Stamatakis Prevention of hypotension during elective cesarean section with a fixed-rate norepinephrine infusion versus a fixed-rate phenylephrine infusion. Α double-blinded randomized controlled trialInt J Surg202084419

4 

AV Rai S Prakash H Chellani P Mullick R Wason Comparison of phenylephrine and norepinephrine for treatment of spinal hypotension during elective cesarean delivery- A randomised, double-blind studyJ Anaesthesiol Clin Pharmacol202238344552

5 

D Chen X Qi X Huang Efficacy and safety of different norepinephrine regimens for prevention of spinal hypotension in cesarean section: a randomized trialBiomed Res Int201820182708175

6 

Y Li B Shuai H Huang Prophylactic intravenous norepinephrine for the prevention of hypotension during spinal anesthesia for elective cesarean section: a systematic review and dose-response meta-analysis of randomized controlled trialsFront Pharmacol2023141247214

7 

AM Hasanin SM Amin NA Agiza MK Elsayed S Refaa HA Hussein Norepinephrine Infusion for Preventing Postspinal Anesthesia Hypotension during Cesarean Delivery: A Randomized Dose-finding TrialAnesthesiology201913015562

8 

MA Gropper RD Miller Miller's AnaesthesiaNinth editionElsevier SaundersPhiladelphia2020

9 

K Kouz P Hoppe L Briesenick B Saugel Intraoperative hypotension: Pathophysiology, clinical relevance, and therapeutic approachesIndian J Anaesth2020642906

10 

PM Singh NP Singh M Reschke WDN Kee A Palanisamy DT Monks Vasopressor drugs for the prevention and treatment of hypotension during neuraxial anaesthesia for Caesarean delivery: a Bayesian network meta-analysis of fetal and maternal outcomesBr J Anaesth2020124395107

11 

J Singh J Singh S Mitra LK Anand B Goel M Kaur Comparison of prophylactic phenylephrine and norepinephrine infusion on umbilical arterial pH and maternal blood pressure during spinal anaesthesia for caesarean deliveryIndian J Anaesth202266211521

12 

M Heesen N Hilber K Rijs R Rossaint T Girard FJ Mercier A systematic review of phenylephrine vs. noradrenaline for the management of hypotension associated with neuraxial anaesthesia in women undergoing caesarean sectionAnaesthesia20207568008

13 

D Singh JBS Yadav AK Singh MK Rai Comparing the Effect of Phenylephrine Bolus and Phenylephrine Infusion for Maintaining Arterial Blood Pressure During Cesarean Delivery Under Spinal Anesthesia: A Randomized Prospective StudyCureus2023157e42713

14 

AM Sharkey N Siddiqui K Downey XY Ye J Guevara JCA Carvalho Comparison of Intermittent Intravenous Boluses of Phenylephrine and Norepinephrine to Prevent and Treat Spinal-Induced Hypotension in Cesarean Deliveries: Randomized Controlled TrialAnesth Analg2019129213128

15 

HE Ashagrie TD Filatie DY Melesse SY Mustefa The incidence and factors associated with intraoperative nausea and vomiting during cesarean section under spinal anesthesiaInt J Surg Open2019264954

16 

S Hailu S Mekonen A Shiferaw Prevention and management of postoperative nausea and vomiting after cesarean section: A systematic literature reviewAnn Med Surg (Lond).202275103433

17 

TT Nguyen HC Nguyen ATH Nguyen TH Doan QS Ngo Comparison of intermittent boluses of noradrenaline vs. phenylephrine for spinal anesthesia induced hypotension during cesarean deliveryAnaesth Pain Intensive Care20232755626

18 

WDN Kee SWY Lee FF Ng A Lee Norepinephrine or phenylephrine during spinal anaesthesia for Caesarean delivery: a randomised double-blind pragmatic non-inferiority study of neonatal outcomeBr J Anaesth2020125458895

19 

WDN Kee Norepinephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a 12-month review of individual useInt J Obstet Anesth201730734

20 

J Qian YP Zhao JL Deng LZ Wang F Xiao B Shen Determination of the Relative Potency of Norepinephrine and Phenylephrine Given as Infusions for Preventing Hypotension During Combined Spinal-Epidural Anesthesia for Cesarean Delivery: A Randomized Up-And-Down Sequential Allocation StudyFront Pharmacol202213942005

21 

X Wang X Shen S Liu J Yang S Xu The Efficacy and Safety of Norepinephrine and Its Feasibility as a Replacement for Phenylephrine to Manage Maternal Hypotension during Elective Cesarean Delivery under Spinal AnesthesiaBiomed Res Int2018311869189

22 

YS Hassabelnaby AM Hasanin N Adly MMA Mostafa S Refaat E Fouad Comparison of two Norepinephrine rescue bolus for Management of Post-spinal Hypotension during Cesarean Delivery: a randomized controlled trialBMC Anesthesiol202020184

23 

M Žunić ŠN Krčevski M Kamenik The influence of the infusion of ephedrine and phenylephrine on the hemodynamic stability after subarachnoid anesthesia in senior adults - a controlled randomized trialBMC Anesthesiol2019191207



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.