• Article highlight
  • Article tables
  • Article images

Article History

Received : 27-03-2021

Accepted : 17-04-2021



Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 487

PDF Downloaded: 488


Get Permission Tiwari, Dharmamer, Mohan, Chandra, Yadav, and Rao: Comparison of two insertion techniques for I-Gel placement in paediatric patients: standard vs rotational methods


Introduction

The I-GelTM (Intersurgical, Wokingham, UK) is a second generation supraglottic airway device (SAD) with a moldable, non-inflatable anatomical cuff that greatly aids in maintaining the airway by providing a good seal over the larynx and adjoining structures.1 This device is increasingly being employed for providing ventilation during elective and emergency surgeries. I-Gel has been validated for emergency airway management in the pre-hospital setting too.2, 3, 4

A standard technique similar to LMA insertion is basically used to insert I-Gel. However, it becomes difficult at times to insert I-Gel by the standard technique in children. There are some alternative methods such as rotation of varying degree, inflating the cuff partially, and lateral approaches which have previously been utilized to facilitate the insertion and correct placement of LMA in children.5 In a recent case report, Sen et al have suggested that it may be fruitful to employ the reverse technique for I-Gel insertion, once the standard technique for insertion has failed.6

The benefit of the rotational technique in ensuring a better first attempt success rate for the placement of the ProSeal laryngeal mask airway (LMA) without causing clinically significant hypopharyngeal mucosal trauma has been demonstrated in a number of studies.7, 8, 9 Therefore, we hypothesized that in comparison to the standard technique, the rotational technique would prove to be more beneficial to ensure the correct placement of I-Gel in the posterior hypopharynx, in an early and smooth manner.

Materials and Methods

After securing approval of the Institutional Ethical Committee and obtaining written informed consent from parents; this prospective randomized clinical study was conducted in ASA I and II children, aged between 1and 6 years, undergoing brief elective surgical procedures lasting less than 60 minutes including abdominal (e.g. undescended testis), inguinal (e.g. herniotomy, circumcision), and orthopaedic procedures (e.g. surgeries involving upper and lower extremities). The patients were randomly distributed into two groups (using computer-based block randomization) i.e. Group A (n= 30) employing the standard method, and Group B (n= 30) utilizing the rotational method for placement of I-Gel. Patients with symptoms suggestive of recent/ongoing upper respiratory tract infection, children at increased risk of regurgitation, and children with anticipated difficult airway such as retrognathia, restricted mouth opening, trismus, facial trauma, or occluding mass in the pharyngeal space were excluded from the study.

In the operating theatre standard monitoring (pulse oximetry, NIBP, ECG, capnography and temperature) was connected to the child. After premedication with 0.1mg/kg midazolam and 1μg/kg fentanyl intravenously 10 min before induction, anaesthesia was induced with Propofol (3mg/kg) intravenously and maintained with sevoflurane, oxygen, spontaneous ventilation with regional blocks as indicated. The actual size of the I-Gel was accounted for based on the patients’ bodyweight (size 1.5 for those weighing 5-12 kg, size 2 for those weighing 10–25 kg). In the standard group, the I-Gel was advanced along the hard palate and soft palate into the posterior pharyngeal space. In the rotational group, the I-Gel was rotated 90° in the anticlockwise direction after being introduced into the oral cavity and advanced downwards into the hypopharynx. It was then rotated clockwise to the original alignment, returning it to the standard position in the midline.

Successful I-Gel insertion was confirmed clinically by the ability of the attending anaesthesiologist to insufflate the lungs as indicated by adequate chest lift, no significant resistance or leakage to ventilation, and prompt refilling of the reservoir bag with confirmation on capnography.

Insertion time was recorded as the time from the opening of the patient’s mouth at the start of insertion to confirmation of the proper placement of I-Gel with capnography. The ease of insertion was adjudged by the time taken to complete I-Gel insertion, the number of attempts before proper placement was accomplished, and the resultant complications (if any). An insertion was graded as easy when the anaesthesiologist could ensure the correct placement of I-Gel in the posterior pharyngeal space without encountering resistance in a single manoeuvre. On the contrary, a difficult insertion was one in which appreciable resistance was encountered during insertion or where additional manipulation had to be undertaken to place the device within the hypopharynx. Ease of I-Gel insertion as experienced by the attending anaesthesiologist was subjectively graded on a scale from 1 to 3 (Table 1).

Table 1

Ease of insertion and insertion score

Ease of insertion

Insertion score

Very Easy

1

Easy

2

Difficult

3

The incidence of complications such as cough, laryngospasm‚ strain (resistance against I-Gel insertion) and haemodynamic parameters such as blood pressure, heart rate and oxygen saturation were recorded. Once the child achieved full wakefulness with easy arousability, the supraglottic airway was removed. The I-Gel was observed for blood staining or sign(s) of any other trauma to the airway. The postoperative visit for each child was scheduled in the evening to record the incidence of sore throat (if any).

Statistical analysis

Based on a 95% confidence interval, a total sample size of 60 (30 in each group) was considered adequate for 80% statistical power and 5% level of significance. Results were expressed as frequency or mean ± SD. All data were analyzed using the Statistical Package for the Social Sciences (SPSS) version 16. Unpaired t-test was utilized to compare the means between the two groups related to various parameters. Chi-square test was employed to find out the association between categorical variables. A p-value of < 0.05 was considered significant.

Results

The demographic profiles of patients such as age and gender were similar and comparable in the two groups (Table 2). The mean age of children in group A was 3.88±1.379 years whereas in group B it was 3.97±1.076years

Table 2

Demographic data

Group A (n=30)

Group B

(n=30)

P value

Gender

Male

17 (56.6)

15 (50)

0.611

Female

13 (43.3)

15 (50)

Mean Age

3.88±1.379

3.97±1.076

0.774

Table 3

I-Gel insertion parameters

Parameters

Group A (n=30)

Group B (n=30)

p-valve

Insertion Attempts: 1 / 2 / 3

24 / 6 / 0

29 / 1 / 0

0.040*

Ease of Insertion: Very Easy / Easy / Difficult

24 / 4 / 2

27/ 2 / 1

0.454

Insertion Time (in seconds)

12.35±1.170

12.17±1.085

0.518

Table 4

Haemodynamic and ventilation parameters (mean)

Parameter

Group A (n=30)

Group B (n=30)

p value

Heart rate (before insertion)

101.35±5.289

102.23±6.966

.580

Heart rate (1 minute after insertion)

118.03±4.956

120.67±8.576

.146

MAP (before insertion)

65.52±8.970

61.77±9.793

.124

MAP (after insertion)

68.58 ± 9.124

66.07±10.596

.324

SpO2

100.00±.000

100.00±.000

-

Respiratory rate

19.19±1.778

19.93±3.129

.259

Air leak pressure (cm H2O)

19.32±1.514

19.10±1.583

.577

SBP before insertion (mmHg)

89.84±8.494

86.62±10.133

.187

DBP before insertion (mmHg)

51.87±9.204

48.14±11.498

.169

SBP after insertion (mmHg)

93.68±8.757

89.90±10.016

.124

DBP after insertion (mmHg)

54.45±11.036

50.83±12.441

.237

The success rate of insertion at the first attempt was significantly greater in Group B (P = 0.040). However, the overall success rate of I-Gel placement was similar between the two groups. The time taken for proper placement at the first attempt in Group A (standard technique) was longer vis-a-vis Group B (rotational technique); however, this difference was not statistically significant (Table 3).

The haemodynamic parameters in the two groups i.e. heart rate, mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) increased after I-Gel insertion but the same was not statistically significant (Table 4). Likewise, no significant difference in respiratory rate was observed in the two techniques of I-Gel insertion.

Blood staining of the tip of the device after its removal was recorded in both groups and it was found that 3 (10%) subjects in Group A and 2(6.6%) subjects in group B had evidence of blood staining. This was neither clinically nor statistically significant. There were no episodes of bucking, coughing, laryngospasm, sore throat or hoarse cry in both groups.

Discussion

The I-Gel is a novel, single-use, cuffless SAD manufactured using elastomer gel (styrene-ethylene butadiene styrene). Its shape partially resembles the inflated PLMA. Its design includes a central wide diameter airway tube, a stem that is elliptical in shape, an ‘anatomically’ shaped non-inflatable cuff, an integral bite block and a gastric drain tube.1 These features provide low resistance to gas flow, stability, improved perilaryngeal and pharyngeal seal, and possibly decreased risks of airway occlusion or aspiration.

Beylacq L et al. studied the efficacy of I-Gel in the paediatric population (50 children above 30 kg undergoing short-duration surgery were enrolled).10 The researchers evaluated the I-Gel on various parameters including ease of insertion, airway leak pressure, intraoperative ventilatory parameters and incidence of postoperative complications. The initial attempt success rate for insertion and proper placement was 100%. The authors observed that I-Gel insertion is a relatively easy procedure and appears to be safe for paediatric airway management. Hughes C et al evaluated 154 children managed with I-Gel (size ranging from 1 to 2.5) over a period of 12 months to assess the device efficacy based on certain parameters like successful rate of insertion, seal pressure, confirmation of proper placement by fiberoptic laryngoscopy, ease in placing the gastric tube, manipulations required, and complications during insertion and removal.11 The success in the initial attempt at insertion was 93.5%, whereas complications were observed in 20% of cases. Most of the complications were minor, however, there were few cases of I-Gel displacement leading to a compromised airway. Contrary to the above, none of the subjects in our study experienced any complication whatsoever.

Kim et al. compared two techniques i.e., standard and rotational techniques for I-Gel insertion in 180 anaesthetized adult patients.12 The success rate of proper placement, insertion time, seal pressure and occurrence of complications were assessed. They inferred that the rotational method facilitated a greater success rate of proper I-Gel placement at the initial attempt than the standard method. In addition, the rotational method conferred other advantages over the standard method including an abridged I-Gel placement time, better airway patency and lesser perioperative complications involving the airway. In our study, the success rate of I-Gel insertion at the first attempt was significantly higher while employing the rotational technique (Group B). Our findings suggest that the rotational technique is the better alternative amongst the two methods to ensure rapid and smooth insertion of I-Gel in the paediatric population.

Our study has various limitations. The attending anaesthesiologist was not blinded to the insertion technique. At the same time, it was ensured that the observers entrusted with recording the various parameters were blinded to the grouping of the subjects. A single trained anaesthesiologist went ahead with all insertions in our study and hence it might not be very appropriate to extrapolate the findings to other anaesthesiologists not well versed with the rotational technique. However, it has been validated in two previous studies that even novices enjoy a high success rate in I-Gel insertion.13, 14 We are highly optimistic that our results are suitable for generalization since the success rate at the initial attempt, I-Gel placement time, and airway leak pressure recorded in the standard group (Group A) of our study are comparable to the observations of other researchers.13, 15, 16

Conclusion

This study demonstrates that I-Gel placement employing the rotational method results in an increase in the success rate at the initial attempt, evidently suggestive of the fact that the rotational technique is a better alternative to the standard method. We recommend the use of the rotational technique for ensuring rapid and smooth placement of I-Gel in anaesthetized paediatric patients.

Source of Funding

None.

Conflict of Interest

None.

References

1 

Intersurgical, I-Gel User Guidehttp://www.I-Gel.com/

2 

JJ Gatward TM Cook C Seller Evaluation of the size 4 I-Gel airway in one hundred non-paralysed patientsAnesthesia200863112430

3 

DA Gabbott R Beringer The I-Gel supraglottic airway: a potential role for resuscitation?Resuscitation2007731612

4 

B Richez L Saltel F Banchereau R Torrielli AM Cros A new single use supraglottic airway device with a non-inflatable cuff and an esophageal vent: an observational study of the I-GelAnesth Analg2008106411379

5 

B Ghai JK Makkar N Bhardwaj J Wiq Laryngeal mask airway in children: comparison between rotational, lateral and standard techniquePaediatr Anaesth200818430812

6 

I Sen N Bhardwaj YS Latha Reverse technique for I-Gel supraglottic airway insertionJ Anesthesiol Clin Pharmacol2013291289

7 

JW Hwang HP Park YJ Lim SH Do SC Lee YT Jeon Comparison of two insertion techniques of ProSeal laryngeal mask airway: standard versus 90-degree rotationAnesthesiology20091109057

8 

YT Jeon HS Na SH Park Insertion of the ProSeal laryngeal mask airway is more successful with the 90 degrees rotation techniqueCan J Anesth2010572115

9 

MJ Yun JW Hwang SH Park SH Han HP Park JH Kim The 90 degrees rotation technique improves the ease of insertion of the ProSeal laryngeal mask airway in childrenCan J Anesth20115837983

10 

L Beylacq M Bordes F Semjen AM Cros The I-Gel, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: An observational study in childrenActa Anesthesiol Scand20095333769

11 

C Hughes K Place S Berg D Mason A clinical evaluation of the I-Gel supraglottic airway device in childrenPediatr Anaesth201222876571

12 

HC Kim DH Yoo HJ Kim YT Jeon JW Hwang HP Park A prospective randomized comparison of two insertion methods for I-Gel placement in anaesthetized paralyzed patients: standard vs. rotational techniqueAnesthesia201469772934

13 

L Theiler M Gutzmann M Kleine-Brueggeney N Urwyler B Kaempfen Greif R. i-gelTM supraglottic airway in clinical practice: a prospective observational multicentre studyBr J Anaesth20121099905

14 

NM Wharton B Gibbison DA Gabbott GM Haslam N Muchatuta TM Cook I-gel insertion by novices in manikins and patientsAnaesthesia2008639915

15 

WJ Shin YS Cheong HS Yang T Nishiyama The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patientsEur J Anaesthesiol201027598601

16 

T Sanuki R Uda S Sugioka E Daigo H Son M Akatsuka The influence of head and neck position on ventilation with the i-gel airway in paralysed, anaesthetised patientsEur J Anaesthesiol20112885979



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.