Print ISSN:-2394-4781

Online ISSN:-2394-4994

CODEN : IJCACT


Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 1502

PDF Downloaded: 632


Are we glorifying the use of video laryngoscopes? A randomized control study comparing C-MAC(R) laryngoscope and McCoy blade for tracheal intubation in patients undergoing general anaesthesia with simulated immobilization of cervical spine


Full Text PDF


Original Article

Author Details : Gunaseelan Mirunalini, Balasubramaniam Gayathri*, Meshak Dhas, Mohana Vatsalya Koka, Balaji Ramraj

Volume : 6, Issue : 3, Year : 2019

Article Page : 377-381

https://doi.org/10.18231/j.ijca.2019.072



Suggest article by email

Get Permission

Abstract

Objective: Intubating patients with cervical spine injury is a challenge as the cervical spine is immobilized to prevent neurological damage. Although Fibre optic intubation is gold standard, many anaesthetist’s use video laryngoscope or McCoy blade for intubation. The purpose of this study was to compare the efficacy of C-MAC(R) video laryngoscope and direct laryngoscope with McCoy blade in intubating patients with cervical spine immobilization simulating cervical spine injuries.
Materials and Methods: A total of 60 patients undergoing general anaesthesia were randomized into two groups. Intubation was attempted using C-MAC(R) video laryngoscope and McCoy blade after cervical immobilization using hard collar. Time to intubate, hemodynamic parameters and Intubation difficulty score was used to compare the groups.
Result: The laryngoscopic views and success of intubation was comparable in both video laryngoscope and Mc Coy group (30/30; 100% success in both the groups). The time to intubate was found to be less in McCoy group (29.83 ± 1.46 s and 25.67 ± 2.04 s) when compared to C-MAC (R) video laryngoscope. The intubation response was lesser in C-MAC compared to McCoy blade (82.97±7.23 s and 88.30±6 s). Time taken for the hemodynamic to return to baseline was the same in the groups (8.67±1.52 s and 9.13±1.25 s).
Conclusion: Direct laryngoscopy and intubation with McCoy blade is faster when compared to C-MAC(R) video laryngoscope; but with exaggerated intubation response].

Keywords: Laryngoscopy, Intubation, Cervical spine immobilization, Hemodynamics.



How to cite : Mirunalini G, Gayathri B, Dhas M, Koka M V, Ramraj B, Are we glorifying the use of video laryngoscopes? A randomized control study comparing C-MAC(R) laryngoscope and McCoy blade for tracheal intubation in patients undergoing general anaesthesia with simulated immobilization of cervical spine. Indian J Clin Anaesth 2019;6(3):377-381


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.