Original Article
Author Details :
Volume : 5, Issue : 4, Year : 2018
Article Page : 569-575
https://doi.org/10.18231/2394-4994.2018.0108
Abstract
Maintenance of airway during anaesthesia is very important to anaesthesiologist. A prospective, randomized study was conducted in 90 patients (ASA-I & II) posted for various surgeries under general anaesthesia with endotracheal intubation to evaluate differences in glottic view, attempts and duration of laryngoscopy and intubation attempts along with hemodynamic variability associated with the three blades- Macintosh, McCoy and Miller laryngoscope blade. Patients were randomly allocated in three groups. In first group laryngoscopy was done with Macintosh blade, in second group with Miller blade, in third group with McCoy blade.
In this study it was found that McCoy laryngoscope is distinctly superior to the Macintosh and Miller with less hemodynamic changes and better glottic visualization. Degree of difficulty in intubation was more with Miller blade in comparison to Macintosh and McCoy blade which is statistically significant (p value < 0>
Keywords: Cormack lehane grade, Macintosh blade, McCoy blade, Miller blade, Degree of difficulty in intubation.
How to cite : Dwivedi G, Gupta L, A comparative study of laryngeal view and pressor response by using three different blades- Macintosh, miller and Mccoy laryngoscopes. Indian J Clin Anaesth 2018;5(4):569-575
This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.