Print ISSN:-2394-4781

Online ISSN:-2394-4994

CODEN : IJCACT


Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 1037

PDF Downloaded: 622


Evaluation of hemodynamic changes with different abdominal pressure for laproscopic cholecystectomy using advanced cardiac output (Flo-Trac) monitoring


Full Text PDF


Original Article

Author Details : Joy Biswas, Pravin Kumar Das*, Deepak Malviya

Volume : 7, Issue : 2, Year : 2020

Article Page : 295-301

https://doi.org/10.18231/j.ijca.2020.053



Suggest article by email

Get Permission

Abstract

Background and Aims: During laparoscopic procedures, hemodynamic stability is of great concern. This
study was carried out to evaluate hemodynamic Changes with different intra- abdominal pressure (IAP) for
laparoscopic cholecystectomy using Advanced Cardiac Output (FloTrac) Monitoring.
Materials and Methods: In this Prospective, randomized and observational study, total 90 patients ASA
grade I, II scheduled for laparoscopic cholecystectomy were randomly allocated to three groups: Group
I :10-12mm hg, groupII-13-15mmhg, Group III- > 15mmhg. Central venous line and arterial cannula
was secured before induction and connected to FloTrac monitor. Heart rate (HR), Cardiac index (CI),
Systemic vascular resistance index (SVRI), Stroke volume variation (SVV), Oxygen saturation (SPO2)
were monitored at various interval. For Statistical analysis student t-test and ANOVA test were used.
Results: At all time intervals, HR of Group I was found to be lower than Group II and Group III except
at insufflation. CI (Cardiac Index) of Group I was also found to be lower than that of Group II and that of
Group III was lower than that of Group II at all time intervals. At all time periods values of SVRI, SVV of
Group I were found to be lower than that of Group II and Group III. SVRI, SVV of Group II were found to
be lower than that of Group III.
Conclusions: IAP value above 15mm Hg seems to affect the hemodynamics significantly. Study showed
that the IAP rise from 10-12 to 13-15 does not influence hemodynamics significantly, and could be adjudged
relatively safe.

Keywords: Intra-abdominal pressure, Laparoscopic cholecystectomy, Hemodynamic paramaters, Cardiac index, Systemic vascular resistance index, Stroke volume variation flow-trac.



How to cite : Biswas J, Das P K, Malviya D, Evaluation of hemodynamic changes with different abdominal pressure for laproscopic cholecystectomy using advanced cardiac output (Flo-Trac) monitoring. Indian J Clin Anaesth 2020;7(2):295-301


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.